新闻中心

EEPW首页 > 模拟技术 > 设计应用 > Using the DS32kHz with Dallas

Using the DS32kHz with Dallas

作者:时间:2011-12-28来源:网络收藏
Abstract: This application note describes how to reduce current consumption when using the with Real-Time Clocks (RTCs).

Overview

This application note is intended to answer some frequently asked questions about using the TCXO (temperature-compensated crystal oscillator) and Semiconductor real-time clocks (RTCs).

Using the

The DS32kHz has four pins that are required for operation: VCC, VBAT, GND, and 32kHz_OUT. The VCC, VBAT, and GND are power supply connections and must either be connected to a positive supply or grounded. The 32kHz_OUT signal is intended to drive the X1 input of the RTC. The X2 pin of the RTC should be allowed to float when driving the X1 input with an oscillator.

The DS32kHz ICC and IBAT specifications are measured with no output load. The input characteristics of the oscillator on a RTC will determine how much additional current the DS32kHz will consume. The additional current can significantly increase the size of the battery needed for operation.

Choosing an RTC

Semiconductor has a wide selection of RTCs from which to choose. Some of these devices were designed using a P-WELL process while the more recent devices have been designed using the first-generation N-WELL process. The second-generation N-WELL RTCs incorporate improvements that reduce the current consumption of the TCXO/RTC combination. The following data shows the current consumed by typical devices from each process. The data were taken at a battery voltage of 3.5V at +25°C.

KEY:
Ind = Individual Currents; DS32kHz with output open, RTC with crystal attached and running.
Direct = DS32kHz driving the RTC X1 input directly.
RC = DS32kHz driving the RTC with a 1MΩ resistor in series with a 100pF capacitor to the X1 input.

Table 1. N-WELL (First Generation)
ModeDS32kHz IBAT (µA)DS1306 IBAT (nA)
Ind1.60518
Direct11.9386
RC2.14584







Table 2. N-WELL (Second Generation)
ModeDS32kHz IBAT (µA)DS1337 ICC (nA)
Ind1.59612
Direct3.73626
RC2.11622

Table 3. P-WELL
ModeDS32kHz IBAT (µA)DS1202 IBAT (nA)
Ind1.63625
Direct87.13,410
RC2.17685

Note the RTC in each of the aforementioned tables are different RTCs. This accounts for the difference in the clock currents when comparing the tables.

If the RTC has an oscillator-enable bit, the oscillator must be enabled. If the bit is not enabled, additional current will be drawn and the clock might not operate.

Table 4. RTC LIST
P-WELL DevicesFirst Generation N-WELL DevicesSecond Generation N-WELL Devices
DS1202DS12885DS1337
DS12885DS1302DS1338
DS1283DS1305/DS1306DS1339
DS1284DS1307DS1672
DS1384DS1315
DS14285DS1500/DS1501
DS1384DS1315
DS1602
DS1670/DS1673/DS1677
DS1685
DS1688/DS1689
DS17285/DS17485/DS17885

Summary

When using P-WELL and first-generation N-WELL RTC devices, use an RC circuit to achieve the minimum possible timekeeping current.

The second-generation N-WELL devices use only slightly more current with an RC circuit


关键词: DS32kHz Dallas